This module installs and configures the apcupsd UPS monitor for APC UPS units.
Usage
This module has only one class, and takes the following parameters:
upsname
Give your UPS a name in log files and such. It should be 8 characters or less.
upscable
Defines the type of cable connecting the UPS to your computer. Choose from:
simple
, smart
, ether
, usb
. Default: usb
.
upstype
Define the type of UPS you have. Choose from apcsmart
, usb
, net
, snmp
,
dumb
, pcnet
. Default: usb
.
device
For USB UPSes, leave $device
blank. For other UPS types, you must specify an
appropriate port or address. Consult the table for example values for $device
.
Default: undef
.
$upstype |
$device |
---|---|
apcsmart |
/dev/ttyS0 |
usb |
<BLANK> |
net |
hostname:port |
snmp |
hostname:port:vendor:community |
dumb |
/dev/ttyS0 |
pcnet |
ipaddr:username:passphrase:port |
onbatterydelay
Time in seconds from when a power failure is detected until we react to it with
an onbattery event. Default: 6
.
batterylevel
If during a power failure, the remaining battery percentage (as reported by the
UPS) is below or equal to $batterylevel
, apcupsd will initiate a system shutdown.
Default: 5
.
minutes
If during a power failure, the remaining runtime in minutes (as calculated
internally by the UPS) is below or equal to $minutes
, apcupsd will initiate a
system shutdown. Default: 3
.
netserver
Enables the network information server. If netstatus is on, a network information
server process will be started for serving the STATUS and EVENT data over the
network (used by CGI programs). Choose from: on
, off
. Default: on
.
Limitations
This module was written for use with CentOS, although it should work on other distributions too.
Currently this module only supports configuring a single UPS attached to the local system. Future versions may support multiple UPSes on a single system or network communication between systems sharing the same UPS, to co-ordinate shutdown.
Development
If you can contribute to improve this module, please send a pull request.
Release Notes
0.1.0
Initial release, with support for a single UPS on a single system.
0.2.0
Added support for setting mail destination address for events scripts.
0.2.1
Add defaults file for Debian, as service fails to run without ISCONFIGURED=yes in this file (thanks @legooolas)